Description
We are facing a similar issue to the one that was fixed in #69 - just when using the SpiBus
instead of SpiDevice
.
Running this code:
pub mod error;
use error::Result;
use ftdi_embedded_hal::eh1::digital::OutputPin;
use ftdi_embedded_hal::eh1::spi::{SpiBus, SpiDevice};
use ftdi_embedded_hal::libftd2xx::FtdiCommon;
use ftdi_embedded_hal::{self as hal};
fn main() -> Result<()> {
let mut ftdi = ftdi_embedded_hal::libftd2xx::Ft4232h::with_description("Quad RS232-HS B")?;
println!("found ftdi with device info: {:?}", ftdi.device_info());
let hal = hal::FtHal::init_default(ftdi)?;
let mut device = hal.spi()?;
let mut cs = hal.ad3()?;
cs.set_high()?;
device.set_clock_polarity(hal::eh0::spi::Polarity::IdleHigh);
device.write(&[0; 1])?;
cs.set_low()?;
let command = [1, 0xff, 0x80];
device.write(&command)?;
cs.set_high()?;
Ok(())
}
What we get is this:

Where you can see too short clocks at the start of the communication and between bytes. If we use the SpiDevice
this does not happen.
I currently don't see a way to work around this since there is no public API with which I could "fix" the polarity of the clock, similar to what was done in #69. A possible fix would be to preset the clock bit in FtInner::lower
in the set_clock_polarity
call - we'll be testing that.
Or did we mess up here / overlook some function?
To preempt the question: we are not using SpiDevice
since we are communicating with a device where we need to poll for a non-zero byte, without releasing the CS pin. I don't see a way to do this with the features of the SpiDevice
trait.