@@ -923,7 +923,8 @@ class battery_mode(Enum):
923923 dataType = UINT16 ,
924924 entityType = TextReadEntityType (generic_alarm_ledger ),
925925 ),
926- "battery_mode" : RegisterInfo (327 , UINT16 , entityType = SelectWriteType (battery_mode )),
926+ # disabled for now as it is specified as RESERVED (not yet active) in the documentation
927+ # "battery_mode": RegisterInfo(327, UINT16, entityType=SelectWriteType(battery_mode)),
927928}
928929
929930battery_registers_2 = {
@@ -1073,9 +1074,9 @@ class battery_balancer_status(Enum):
10731074}
10741075
10751076battery_info_registers = {
1076- "battery_mode_2" : RegisterInfo (
1077- 1319 , UINT16 , entityType = SelectWriteType (battery_mode_alternative )
1078- ),
1077+ # "battery_mode_2": RegisterInfo(
1078+ # 1319, UINT16, entityType=SelectWriteType(battery_mode_alternative)
1079+ # ),
10791080 "battery_balancer_status" : RegisterInfo (
10801081 1320 , UINT16 , entityType = TextReadEntityType (battery_balancer_status )
10811082 ),
@@ -1094,7 +1095,7 @@ class battery_balancer_status(Enum):
10941095 "battery_errors_smartlithium_invalidconfiguration" : RegisterInfo (
10951096 1324 , UINT16
10961097 ), # This has no decode values for returned numbers
1097- "battery_connection_information" : RegisterInfo (1328 , STRING (8 )),
1098+ # "battery_connection_information": RegisterInfo(1328, STRING(8)),
10981099}
10991100
11001101
@@ -3672,5 +3673,4 @@ class system_battery_state(Enum):
36723673 "system_invertercharger_registers" : system_invertercharger_registers ,
36733674 "system_pvac_registers" : system_pvac_registers ,
36743675 "system_power_registers_2" : system_power_registers_2 ,
3675-
36763676}
0 commit comments