Notifications
You must be signed in to change notification settings - Fork 28
Description
I'm following the Ce2O3_csc_w90 tutorials.I ran the following command
mpirun -np 1 solid_dmft > dmft.out &
The dmft_config.toml is
[general]
seedname = "ce2o3"
jobname = "b10-U6.46-J0.46"
csc = true
eta = 0.5
n_iw = 100
n_tau = 5001
n_iter_dmft_first = 2
n_iter_dmft_per = 1
n_iter_dmft = 5
enforce_off_diag = false
block_threshold = 1e-03
h_int_type = "density_density"
h_int_basis = "qe"
U = 6.46
J = 0.46
beta = 10
prec_mu = 0.1
sigma_mix = 1.0
g0_mix = 1.0
dc_type = 0
dc = true
dc_dmft = true
calc_energies = true
h5_save_freq = 1
[solver]
type = "hubbardI"
n_l = 15
#store_solver = false
measure_G_l = false
measure_density_matrix = true
[dft]
dft_code = "qe"
n_cores = 1
mpi_env = "default"
projector_type = "w90"
dft_exec = "pw.x"
w90_tolerance = 1e-1
I got the following error:
Traceback (most recent call last):
File "/usr/bin/solid_dmft", line 45, in
run_solid_dmft.main(sys.argv)
File "/usr/lib/python3/dist-packages/solid_dmft/main.py", line 151, in main
run_dmft(params, config_file_name)
File "/usr/lib/python3/dist-packages/solid_dmft/main.py", line 95, in run_dmft
csc_flow_control(general_params, solver_params, dft_params, gw_params, advanced_params)
File "/usr/lib/python3/dist-packages/solid_dmft/csc_flow.py", line 326, in csc_flow_control
is_converged, sum_k = dmft_cycle(general_params, solver_params, advanced_params, dft_params,
File "/usr/lib/python3/dist-packages/solid_dmft/dmft_cycle.py", line 487, in dmft_cycle
h_int, gw_params = interaction_hamiltonian.construct(sum_k, general_params, solver_type_per_imp, gw_params)
File "/usr/lib/python3/dist-packages/solid_dmft/dmft_tools/interaction_hamiltonian.py", line 556, in construct
Umat_full = _generate_four_index_u_matrix(sum_k, general_params, icrsh)
File "/usr/lib/python3/dist-packages/solid_dmft/dmft_tools/interaction_hamiltonian.py", line 382, in _generate_four_index_u_matrix
util.spherical_to_cubic(l=l, convention=general_params['h_int_basis'])
File "/usr/lib/python3/dist-packages/triqs/operators/util/U_matrix.py", line 358, in spherical_to_cubic
raise ValueError("spherical_to_cubic: [wien2k, wannier90, qe] convention implemented only for l=0,1,2")
ValueError: spherical_to_cubic: [wien2k, wannier90, qe] convention implemented only for l=0,1,2
I am using solid_dmft version 3.3.X, TRIQS, and Quantum ESPRESSO version 7.4.1.
Please tell me how to fix the error.Thank you.