Notifications
You must be signed in to change notification settings - Fork 100
Added detection between session and main meter energy values #919
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Changes from all commits
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -11,7 +11,7 @@ | |
|
||
from homeassistant.components.persistent_notification import DOMAIN as PN_DOMAIN | ||
from homeassistant.config_entries import ConfigEntry | ||
from homeassistant.const import STATE_OK, STATE_UNAVAILABLE, TIME_MINUTES | ||
from homeassistant.const import STATE_OK, STATE_UNAVAILABLE, STATE_UNKNOWN, TIME_MINUTES | ||
from homeassistant.core import HomeAssistant | ||
from homeassistant.helpers import device_registry, entity_component, entity_registry | ||
import homeassistant.helpers.config_validation as cv | ||
|
@@ -245,6 +245,12 @@ def get_metric(self, cp_id: str, measurand: str): | |
return self.charge_points[cp_id]._metrics[measurand].value | ||
return None | ||
|
||
def del_metric(self, cp_id: str, measurand: str): | ||
"""Set given measurand to None.""" | ||
if cp_id in self.charge_points: | ||
self.charge_points[cp_id]._metrics[measurand].value = None | ||
return None | ||
|
||
def get_unit(self, cp_id: str, measurand: str): | ||
"""Return unit of given measurand.""" | ||
if cp_id in self.charge_points: | ||
|
@@ -353,6 +359,7 @@ def __init__( | |
self.received_boot_notification = False | ||
self.post_connect_success = False | ||
self.tasks = None | ||
self._charger_reports_session_energy = False | ||
self._metrics = defaultdict(lambda: Metric(None, None)) | ||
self._metrics[cdet.identifier.value].value = id | ||
self._metrics[csess.session_time.value].unit = TIME_MINUTES | ||
|
@@ -1073,6 +1080,30 @@ def on_meter_values(self, connector_id: int, meter_value: dict, **kwargs): | |
|
||
transaction_id: int = kwargs.get(om.transaction_id.name, 0) | ||
|
||
# If missing meter_start or active_transaction_id try to restore from HA states. If HA | ||
# does not have values either, generate new ones. | ||
if self._metrics[csess.meter_start.value].value is None: | ||
value = self.get_ha_metric(csess.meter_start.value) | ||
if value is None: | ||
value = self._metrics[DEFAULT_MEASURAND].value | ||
else: | ||
value = float(value) | ||
_LOGGER.debug( | ||
f"{csess.meter_start.value} was None, restored value={value} from HA." | ||
) | ||
self._metrics[csess.meter_start.value].value = value | ||
if self._metrics[csess.transaction_id.value].value is None: | ||
value = self.get_ha_metric(csess.transaction_id.value) | ||
if value is None: | ||
value = kwargs.get(om.transaction_id.name) | ||
else: | ||
value = int(value) | ||
_LOGGER.debug( | ||
f"{csess.transaction_id.value} was None, restored value={value} from HA." | ||
) | ||
self._metrics[csess.transaction_id.value].value = value | ||
self.active_transaction_id = value | ||
|
||
transaction_matches: bool = False | ||
# match is also false if no transaction is in progress ie active_transaction_id==transaction_id==0 | ||
if transaction_id == self.active_transaction_id and transaction_id != 0: | ||
|
@@ -1099,8 +1130,25 @@ def on_meter_values(self, connector_id: int, meter_value: dict, **kwargs): | |
if unit == DEFAULT_POWER_UNIT: | ||
self._metrics[measurand].value = float(value) / 1000 | ||
self._metrics[measurand].unit = HA_POWER_UNIT | ||
elif unit == DEFAULT_ENERGY_UNIT: | ||
if transaction_matches: | ||
elif unit == DEFAULT_ENERGY_UNIT or "Energy" in str(measurand): | ||
if self._metrics[csess.meter_start.value].value == 0: | ||
# Charger reports Energy.Active.Import.Register directly as Session energy for transactions | ||
self._charger_reports_session_energy = True | ||
if ( | ||
transaction_matches | ||
and self._charger_reports_session_energy | ||
and measurand == DEFAULT_MEASURAND | ||
and connector_id | ||
): | ||
self._metrics[csess.session_energy.value].value = ( | ||
float(value) / 1000 | ||
) | ||
self._metrics[csess.session_energy.value].extra_attr[ | ||
cstat.id_tag.name | ||
] = self._metrics[cstat.id_tag.value].value | ||
elif ( | ||
transaction_matches or self._charger_reports_session_energy | ||
): | ||
self._metrics[measurand].value = float(value) / 1000 | ||
self._metrics[measurand].unit = HA_ENERGY_UNIT | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Same applies here, suggest moving your meter start logic outside into a separate if statement |
||
else: | ||
|
@@ -1118,15 +1166,6 @@ def on_meter_values(self, connector_id: int, meter_value: dict, **kwargs): | |
# _LOGGER.debug("Meter data not yet processed: %s", unprocessed) | ||
if unprocessed is not None: | ||
self.process_phases(unprocessed) | ||
if csess.meter_start.value not in self._metrics: | ||
self._metrics[csess.meter_start.value].value = self._metrics[ | ||
DEFAULT_MEASURAND | ||
] | ||
if csess.transaction_id.value not in self._metrics: | ||
self._metrics[csess.transaction_id.value].value = kwargs.get( | ||
om.transaction_id.name | ||
) | ||
self.active_transaction_id = kwargs.get(om.transaction_id.name) | ||
if transaction_matches: | ||
self._metrics[csess.session_time.value].value = round( | ||
( | ||
|
@@ -1136,7 +1175,10 @@ def on_meter_values(self, connector_id: int, meter_value: dict, **kwargs): | |
/ 60 | ||
) | ||
self._metrics[csess.session_time.value].unit = "min" | ||
if self._metrics[csess.meter_start.value].value is not None: | ||
if ( | ||
self._metrics[csess.meter_start.value].value is not None | ||
and not self._charger_reports_session_energy | ||
): | ||
self._metrics[csess.session_energy.value].value = float( | ||
self._metrics[DEFAULT_MEASURAND].value or 0 | ||
) - float(self._metrics[csess.meter_start.value].value) | ||
|
@@ -1313,7 +1355,10 @@ def on_stop_transaction(self, meter_stop, timestamp, transaction_id, **kwargs): | |
) | ||
self.active_transaction_id = 0 | ||
self._metrics[cstat.stop_reason.value].value = kwargs.get(om.reason.name, None) | ||
if self._metrics[csess.meter_start.value].value is not None: | ||
if ( | ||
self._metrics[csess.meter_start.value].value is not None | ||
and not self._charger_reports_session_energy | ||
): | ||
self._metrics[csess.session_energy.value].value = int( | ||
meter_stop | ||
) / 1000 - float(self._metrics[csess.meter_start.value].value) | ||
|
@@ -1361,6 +1406,20 @@ def get_metric(self, measurand: str): | |
"""Return last known value for given measurand.""" | ||
return self._metrics[measurand].value | ||
|
||
def get_ha_metric(self, measurand: str): | ||
"""Return last known value in HA for given measurand.""" | ||
entity_id = "sensor." + "_".join( | ||
[self.central.cpid.lower(), measurand.lower().replace(".", "_")] | ||
) | ||
try: | ||
value = self.hass.states.get(entity_id).state | ||
except Exception as e: | ||
_LOGGER.debug(f"An error occurred when getting entity state from HA: {e}") | ||
return None | ||
if value == STATE_UNAVAILABLE or value == STATE_UNKNOWN: | ||
return None | ||
return value | ||
|
||
def get_extra_attr(self, measurand: str): | ||
"""Return last known extra attributes for given measurand.""" | ||
return self._metrics[measurand].extra_attr | ||
|
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,4 @@ | ||
homeassistant>=2023.1.0b1 | ||
ocpp==0.19.0 | ||
websockets==11.0.3 | ||
jsonschema==4.19.0 |
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -11,6 +11,7 @@ | |
SERVICE_TURN_ON, | ||
) | ||
from homeassistant.const import ATTR_ENTITY_ID | ||
import pytest | ||
from pytest_homeassistant_custom_component.common import MockConfigEntry | ||
import websockets | ||
|
||
|
@@ -44,6 +45,7 @@ | |
from .const import MOCK_CONFIG_DATA, MOCK_CONFIG_DATA_2 | ||
|
||
|
||
@pytest.mark.timeout(60) # Set timeout to 60 seconds for this test | ||
async def test_cms_responses(hass, socket_enabled): | ||
"""Test central system responses to a charger.""" | ||
|
||
|
@@ -227,6 +229,63 @@ async def test_services(hass, socket_enabled): | |
|
||
await asyncio.sleep(1) | ||
|
||
# test restore feature of meter_start and active_tranasction_id. | ||
async with websockets.connect( | ||
"ws://127.0.0.1:9000/CP_1_res_vals", | ||
subprotocols=["ocpp1.6"], | ||
) as ws: | ||
# use a different id for debugging | ||
cp = ChargePoint("CP_1_restore_values", ws) | ||
cp.active_transactionId = None | ||
# send None values | ||
try: | ||
await asyncio.wait_for( | ||
asyncio.gather( | ||
cp.start(), | ||
cp.send_meter_periodic_data(), | ||
), | ||
timeout=5, | ||
) | ||
except asyncio.TimeoutError: | ||
pass | ||
# check if None | ||
assert cs.get_metric("test_cpid", "Energy.Meter.Start") is None | ||
assert cs.get_metric("test_cpid", "Transaction.Id") is None | ||
# send new data | ||
try: | ||
await asyncio.wait_for( | ||
asyncio.gather( | ||
cp.send_start_transaction(12344), | ||
cp.send_meter_periodic_data(), | ||
), | ||
timeout=5, | ||
) | ||
except asyncio.TimeoutError: | ||
pass | ||
# save for reference the values for meter_start and transaction_id | ||
saved_meter_start = int(cs.get_metric("test_cpid", "Energy.Meter.Start")) | ||
saved_transactionId = int(cs.get_metric("test_cpid", "Transaction.Id")) | ||
# delete current values from api memory | ||
cs.del_metric("test_cpid", "Energy.Meter.Start") | ||
cs.del_metric("test_cpid", "Transaction.Id") | ||
# send new data | ||
try: | ||
await asyncio.wait_for( | ||
asyncio.gather( | ||
cp.send_meter_periodic_data(), | ||
), | ||
timeout=5, | ||
) | ||
except asyncio.TimeoutError: | ||
pass | ||
await ws.close() | ||
|
||
# check if restored old values from HA when api have lost the values, i.e. simulated reboot of HA | ||
assert int(cs.get_metric("test_cpid", "Energy.Meter.Start")) == saved_meter_start | ||
assert int(cs.get_metric("test_cpid", "Transaction.Id")) == saved_transactionId | ||
|
||
await asyncio.sleep(1) | ||
|
||
# test ocpp messages sent from charger to cms | ||
async with websockets.connect( | ||
"ws://127.0.0.1:9000/CP_1_norm", | ||
|
@@ -245,10 +304,11 @@ async def test_services(hass, socket_enabled): | |
cp.send_security_event(), | ||
cp.send_firmware_status(), | ||
cp.send_data_transfer(), | ||
cp.send_start_transaction(), | ||
cp.send_start_transaction(12345), | ||
cp.send_meter_err_phases(), | ||
cp.send_meter_line_voltage(), | ||
cp.send_meter_periodic_data(), | ||
cp.send_main_meter_clock_data(), | ||
# add delay to allow meter data to be processed | ||
cp.send_stop_transaction(2), | ||
), | ||
|
@@ -260,6 +320,9 @@ async def test_services(hass, socket_enabled): | |
assert int(cs.get_metric("test_cpid", "Energy.Active.Import.Register")) == int( | ||
1305570 / 1000 | ||
) | ||
assert int(cs.get_metric("test_cpid", "Energy.Session")) == int( | ||
(54321 - 12345) / 1000 | ||
) | ||
assert int(cs.get_metric("test_cpid", "Current.Import")) == int(0) | ||
assert int(cs.get_metric("test_cpid", "Voltage")) == int(228) | ||
assert cs.get_unit("test_cpid", "Energy.Active.Import.Register") == "kWh" | ||
|
@@ -310,6 +373,43 @@ async def test_services(hass, socket_enabled): | |
|
||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. adding |
||
await asyncio.sleep(1) | ||
|
||
# test ocpp messages sent from charger that don't support errata 3.9 | ||
# i.e. "Energy.Meter.Start" starts from 0 for each session and "Energy.Active.Import.Register" | ||
# reports starting from 0 Wh for every new transaction id. Total main meter values are without transaction id. | ||
async with websockets.connect( | ||
"ws://127.0.0.1:9000/CP_1_non_er_3.9", | ||
subprotocols=["ocpp1.6"], | ||
) as ws: | ||
# use a different id for debugging | ||
cp = ChargePoint("CP_1_non_errata_3.9", ws) | ||
try: | ||
await asyncio.wait_for( | ||
asyncio.gather( | ||
cp.start(), | ||
cp.send_start_transaction(0), | ||
cp.send_meter_periodic_data(), | ||
nlindn marked this conversation as resolved.
Show resolved
Hide resolved
|
||
cp.send_main_meter_clock_data(), | ||
# add delay to allow meter data to be processed | ||
cp.send_stop_transaction(2), | ||
), | ||
timeout=5, | ||
) | ||
except asyncio.TimeoutError: | ||
pass | ||
await ws.close() | ||
|
||
# Last sent "Energy.Active.Import.Register" value without transaction id should be here. | ||
assert int(cs.get_metric("test_cpid", "Energy.Active.Import.Register")) == int( | ||
67230012 / 1000 | ||
) | ||
assert cs.get_unit("test_cpid", "Energy.Active.Import.Register") == "kWh" | ||
|
||
# Last sent "Energy.Active.Import.Register" value with transaction id should be here. | ||
assert int(cs.get_metric("test_cpid", "Energy.Session")) == int(1305570 / 1000) | ||
assert cs.get_unit("test_cpid", "Energy.Session") == "kWh" | ||
|
||
await asyncio.sleep(1) | ||
|
||
# test ocpp rejection messages sent from charger to cms | ||
cs.charge_points["test_cpid"].received_boot_notification = False | ||
cs.charge_points["test_cpid"].post_connect_success = False | ||
|
@@ -604,12 +704,12 @@ async def send_data_transfer(self): | |
resp = await self.call(request) | ||
assert resp.status == DataTransferStatus.accepted | ||
|
||
async def send_start_transaction(self): | ||
async def send_start_transaction(self, meter_start: int = 12345): | ||
"""Send a start transaction notification.""" | ||
request = call.StartTransactionPayload( | ||
connector_id=1, | ||
id_tag="test_cp", | ||
meter_start=12345, | ||
meter_start=meter_start, | ||
timestamp=datetime.now(tz=timezone.utc).isoformat(), | ||
) | ||
resp = await self.call(request) | ||
|
@@ -871,6 +971,30 @@ async def send_meter_err_phases(self): | |
resp = await self.call(request) | ||
assert resp is not None | ||
|
||
async def send_main_meter_clock_data(self): | ||
"""Send periodic main meter value. Main meter values dont have transaction_id.""" | ||
while self.active_transactionId == 0: | ||
await asyncio.sleep(1) | ||
request = call.MeterValuesPayload( | ||
connector_id=1, | ||
meter_value=[ | ||
{ | ||
"timestamp": "2021-06-21T16:15:09Z", | ||
"sampledValue": [ | ||
{ | ||
"value": "67230012", | ||
"context": "Sample.Clock", | ||
"format": "Raw", | ||
"measurand": "Energy.Active.Import.Register", | ||
"location": "Inlet", | ||
}, | ||
], | ||
} | ||
], | ||
) | ||
resp = await self.call(request) | ||
assert resp is not None | ||
|
||
async def send_meter_clock_data(self): | ||
"""Send periodic meter data notification.""" | ||
self.active_transactionId = 0 | ||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@nlindn this should only be /1000 if unit == DEFAULT_ENERGY_UNIT