Changes from all commits
3dbb15b
71061fd
7167fb1
30c5849
8cbe436
9950a34
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,129 @@ | ||
| package itest | ||
|
|
||
| import ( | ||
| "context" | ||
| "fmt" | ||
|
|
||
| "github.com/lightninglabs/lightning-terminal/litrpc" | ||
| "github.com/lightninglabs/lightning-terminal/subservers" | ||
| "github.com/lightningnetwork/lnd/lnrpc" | ||
| "github.com/lightningnetwork/lnd/lntest/wait" | ||
| "github.com/stretchr/testify/require" | ||
| ) | ||
|
|
||
| // testLitdSurvivesLndShutdown asserts that when lnd stops in integrated mode, | ||
| // litd keeps running and its status endpoint stays reachable, reporting lnd as | ||
| // stopped rather than cascading to a full litd shutdown. | ||
| func testLitdSurvivesLndShutdown(ctx context.Context, net *NetworkHarness, | ||
| t *harnessTest) { | ||
|
|
||
| // Use a dedicated, throwaway node so that stopping its lnd cannot | ||
| // affect any other test. | ||
| node, err := net.NewNode( | ||
| t.t, "lnd-stop", nil, false, true, "--autopilot.disable", | ||
| ) | ||
| require.NoError(t.t, err) | ||
|
|
||
| // The harness ShutdownNode stops litd (via its StopDaemon) and waits | ||
| // for the process to exit, so no manual litd shutdown is needed here. | ||
| defer func() { | ||
| _ = net.ShutdownNode(node) | ||
| }() | ||
|
|
||
| ctxt, cancel := context.WithTimeout(ctx, defaultTimeout) | ||
| defer cancel() | ||
|
|
||
| rawConn, err := connectLitRPC( | ||
| ctxt, node.Cfg.LitAddr(), node.Cfg.LitTLSCertPath, | ||
| node.Cfg.LitMacPath, | ||
| ) | ||
| require.NoError(t.t, err) | ||
| defer func() { _ = rawConn.Close() }() | ||
|
|
||
| statusClient := litrpc.NewStatusClient(rawConn) | ||
|
|
||
| // lnd should be running before we stop it. | ||
| resp, err := statusClient.SubServerStatus( | ||
| ctxt, &litrpc.SubServerStatusReq{}, | ||
| ) | ||
| require.NoError(t.t, err) | ||
|
|
||
| lndStatus, ok := resp.SubServers[subservers.LND] | ||
| require.True(t.t, ok, "expected lnd sub-server status") | ||
| require.True(t.t, lndStatus.Running, "lnd should be running initially") | ||
|
|
||
| // Stop lnd (but not litd) via the lnrpc StopDaemon. The call may return | ||
| // an error as the connection is torn down, which is expected. | ||
| _, _ = node.LightningClient.StopDaemon(ctxt, &lnrpc.StopRequest{}) | ||
|
|
||
| // litd's status endpoint must remain reachable and must report lnd as | ||
| // no longer running, with an error explaining why. We poll because lnd | ||
| // shutdown is asynchronous. | ||
| err = wait.NoError(func() error { | ||
| ctxs, cancels := context.WithTimeout( | ||
| context.Background(), defaultTimeout, | ||
| ) | ||
| defer cancels() | ||
|
|
||
| resp, err := statusClient.SubServerStatus( | ||
| ctxs, &litrpc.SubServerStatusReq{}, | ||
| ) | ||
| if err != nil { | ||
| return fmt.Errorf("litd status endpoint unreachable "+ | ||
| "after lnd stopped: %w", err) | ||
| } | ||
|
|
||
| lndStatus, ok := resp.SubServers[subservers.LND] | ||
| if !ok { | ||
| return fmt.Errorf("no lnd sub-server status returned") | ||
| } | ||
|
|
||
| if lndStatus.Running { | ||
| return fmt.Errorf("lnd still reported as running") | ||
| } | ||
|
|
||
| if lndStatus.Error == "" { | ||
| return fmt.Errorf("lnd error message not yet set") | ||
| } | ||
|
|
||
| return nil | ||
| }, defaultTimeout) | ||
| require.NoError(t.t, err) | ||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. You should also test here that the lit sub-server remains up and running after this, i.e. that
Contributor
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Done. After lnd is reported stopped, the test now checks that the LIT sub-server stays reachable and Running for 3 seconds. |
||
|
|
||
| // litd's process itself must keep running after lnd has stopped: its | ||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This last commit can be squashed with the commit called: |
||
| // status endpoint stays reachable. The LIT sub-server is reported as no | ||
| // longer running, since litd cannot function without lnd, but the | ||
| // endpoint continuing to answer at all is what proves litd did not | ||
| // cascade down with lnd. Check this holds over time. | ||
| err = wait.InvariantNoError(func() error { | ||
| ctxs, cancels := context.WithTimeout( | ||
| context.Background(), defaultTimeout, | ||
| ) | ||
| defer cancels() | ||
|
|
||
| resp, err := statusClient.SubServerStatus( | ||
| ctxs, &litrpc.SubServerStatusReq{}, | ||
| ) | ||
| if err != nil { | ||
| return fmt.Errorf("litd status endpoint must stay "+ | ||
| "reachable after lnd stopped: %w", err) | ||
| } | ||
|
|
||
| litStatus, ok := resp.SubServers[subservers.LIT] | ||
| if !ok { | ||
| return fmt.Errorf("no lit sub-server status returned") | ||
| } | ||
|
|
||
| if litStatus.Running { | ||
| return fmt.Errorf("lit sub-server should be reported " + | ||
| "as stopped once lnd has stopped") | ||
| } | ||
|
|
||
| if litStatus.Error == "" { | ||
| return fmt.Errorf("lit sub-server error message not set") | ||
| } | ||
|
|
||
| return nil | ||
| }, defaultTimeout) | ||
| require.NoError(t.t, err) | ||
| } | ||
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
The 5th argument to
net.NewNodeisremoteMode. Passingtrueruns the test in remote mode, which does not test the integrated mode lifecycle changes introduced in this PR. This should be set tofalseto test the integrated mode behavior.